RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4028

Fagor alarm 4028: The light does not reach the CNC through the optic fiber

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

At power-up the transmitted SERCOS light never returns to the CNC receiver - the ring is optically broken.

Likely causes

  • fiber not seated in optical module (dust in bore)
  • fiber crushed in cable tray or snapped at the strain relief
  • a drive in the ring completely dead (no re-transmission)

Triage note: Cheap test: short-wave the fiber at the CNC IN port - if a flashlight beam reaches it, path exists; then bisect the ring drive-by-drive.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • DDS fiber-optic ring cable (cut to loop length)

    SERCOS fiber-optic cable assembly · Primary suspect

    Request a quote →
  • AXD/SPD module showing blank display

    Dead drive breaking re-transmission · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 4028 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog