Fagor alarm 4029: Communication with the drive cannot be established. No response

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Detected on power-up: a drive expected at a given SERCOSID never answers the CNC. All axes stay stopped with enables removed until communication is established. Verify the ring, addresses and baud rate, then isolate by connecting drives one at a time.

Likely causes

  • Drive does not recognize its SERCOS board (hardware error on display)
  • Drive hung and needs a power cycle
  • Rotary address switch not read correctly at power-up
  • Baud rate mismatch between CNC SERSPD and drive QP11

Triage note: Save the SERCOS LOG before swapping hardware.

Replacement parts