Fagor alarm 4057: ERROR 101: Internal -5 V out of range

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The drive's internal -5 V rail is out of tolerance. Non-resettable via the error-clear input: the unit must be turned off and on once the cause is gone. Axes remain disabled with the CNC's external emergency output activated.

Likely causes

  • Internal power supply defect
  • Shorted or leaking component loading the -5 V rail
  • Aging electrolytics in the drive's low-voltage supply

Replacement parts