Fagor alarm 4057: ERROR 101: Internal -5 V out of range
CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives
What it means
The drive's internal -5 V rail is out of tolerance. Non-resettable via the error-clear input: the unit must be turned off and on once the cause is gone. Axes remain disabled with the CNC's external emergency output activated.
Likely causes
- Internal power supply defect
- Shorted or leaking component loading the -5 V rail
- Aging electrolytics in the drive's low-voltage supply
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
DDS / AXD / SPD drive
drive · Common cause
Need the part urgently?