Fagor alarm 4063: ERROR 107: VeCon card overheated

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Temperature inside the drive enclosure (velocity-control/CPU board area) is too high. The drive issues a category 1 stop; the CNC removes enables and interrupts the part program on all channels. Improve enclosure cooling and let the unit cool down before restart.

Likely causes

  • Cabinet cooling fan failure or clogged filters
  • High ambient temperature around the drive
  • Prolonged operation at the current limit heating the electronics

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4063 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog