Fagor alarm 4065: ERROR 200: Overspeed

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Actual motor speed exceeded SP10 by more than 12%. PWM is cut immediately (category 0 stop) so the motor coasts; the CNC simultaneously drops enables, interrupts the program on all channels and fires the external emergency output. Check feedback integrity and velocity-loop tuning.

Likely causes

  • Position-sensor cable damage causing wrong speed feedback
  • Motor power phase wiring faults
  • Velocity loop poorly adjusted / overshoot on deceleration
  • Command spikes from the upper-level controller

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4065 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog