Fagor alarm 4065: ERROR 200: Overspeed
CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives
What it means
Actual motor speed exceeded SP10 by more than 12%. PWM is cut immediately (category 0 stop) so the motor coasts; the CNC simultaneously drops enables, interrupts the program on all channels and fires the external emergency output. Check feedback integrity and velocity-loop tuning.
Likely causes
- Position-sensor cable damage causing wrong speed feedback
- Motor power phase wiring faults
- Velocity loop poorly adjusted / overshoot on deceleration
- Command spikes from the upper-level controller
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
Motor feedback (encoder/resolver) cable
drive · Check if others ruled out
Need the part urgently?
Send us alarm 4065 with your machine details — typical RFQ turnaround is 24–48h.