What it means

Instantaneous current through the drive module exceeded the hardware limit (about 1.6 x IGbT peak). PWM switches off immediately (category 0 stop) and the CNC executes its full emergency sequence across all channels. Reset once; if it repeats, suspect hardware or gross tuning errors causing current overshoot.

Likely causes

  • Phase-to-phase or phase-to-ground short in motor cable/motor
  • Failed IGBT in the drive output stage
  • Badly tuned current/speed loop causing overshoot
  • Wrong motor data or phase order after service

Triage note: Also surfaces as generic wrapper 4009.