Fagor alarm 4070: ERROR 213: Undervoltage at the IGBT power driver
CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives
What it means
Supply voltage at the IGBT triggering circuits dropped below the level needed to keep the switches fully saturated. PWM is cut (category 0 stop) and the CNC removes enables and aborts all channels. Reset once; a persistent error usually means a failing gate driver or IGBT.
Likely causes
- Defective IGBT gate-driver circuitry
- Failing IGBT pulling the driver rail down
- Internal +15/+18 V supply weakness under load
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
DDS / AXD / SPD drive
drive · Common cause
Need the part urgently?
Send us alarm 4070 with your machine details — typical RFQ turnaround is 24–48h.