Fagor alarm 4070: ERROR 213: Undervoltage at the IGBT power driver

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Supply voltage at the IGBT triggering circuits dropped below the level needed to keep the switches fully saturated. PWM is cut (category 0 stop) and the CNC removes enables and aborts all channels. Reset once; a persistent error usually means a failing gate driver or IGBT.

Likely causes

  • Defective IGBT gate-driver circuitry
  • Failing IGBT pulling the driver rail down
  • Internal +15/+18 V supply weakness under load

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4070 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog