RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4071

Fagor alarm 4071: ERROR 214: Short-circuit

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The drive detected a short-circuit condition at its power output (desaturation/overcurrent signature typical of a bridge shoot-through or load short). PWM is interrupted instantly (category 0 stop) with the CNC dropping enables and aborting every channel. After a safe reset check the motor and its cabling before re-enabling.

Likely causes

  • Motor cable phases shorted or incorrectly phased
  • Insulation failure in the motor windings
  • Crossed/damaged power wiring after maintenance
  • Destroyed inverter IGBT

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4071 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog