Fagor alarm 4072: ERROR 215: Over-voltage at the power bus (Hard)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The drive hardware detected DC bus voltage above the absolute limit, typically because regenerated energy cannot be dissipated. PWM is cut immediately (category 0 stop) and the CNC aborts all channels. Check the ballast/regeneration chain first - most causes are external to the amplifier electronics.

Likely causes

  • Missing connection bridge across the internal ballast terminals
  • External regen resistor disconnected, open or burned out
  • Loose bus-bar connections
  • Very fast decelerations dumping energy faster than the ballast can absorb

Triage note: Hardware-level counterpart of soft errors E304/E306 (4077/4079).