RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4073

Fagor alarm 4073: ERROR 300: Heatsink of the power supply module overheated

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The shared power supply module (PS/XPS or compact-module supply section) reported its heatsink over temperature. The affected axes group stops; the CNC removes enables and aborts all programs. Stop the system several minutes, clean/verify the PSU cooling, and reduce regenerated/demanded power.

Likely causes

  • Power-supply cooling fan failure
  • Blocked PSU ventilation or oil-mist fouling
  • Sustained regeneration or consumption near PSU rating
  • High ambient cabinet temperature

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4073 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog