RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4076

Fagor alarm 4076: ERROR 303: Ballast circuit supply voltage out of range

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The supply voltage feeding the ballast-circuit driver is outside its permitted window, so the braking chopper cannot be guaranteed to switch correctly. PWM is cut (category 0 stop) with the usual CNC-wide shutdown. Contact service; the supply module's driver supply is at fault.

Likely causes

  • Defective ballast gate-driver supply inside the PSU
  • Internal low-voltage supply degradation
  • Component failure in the PSU control electronics

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4076 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog