Fagor alarm 4077: ERROR 304: Over-voltage at the power bus detected by the power supply module

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The power supply module itself measured DC bus overvoltage (as opposed to the drive's own detection). PWM is cut (category 0 stop); the CNC drops enables and aborts all channels. Inspect the regeneration path and wiring with the supply disconnected.

Likely causes

  • Internal ballast bridge/connector missing or loose
  • External regen resistor not connected or open
  • Burned-out ballast resistor
  • Bus bar connections loose

Triage note: Related: E215 (hard, drive-side) and E306 (soft, drive-side).

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4077 with your machine details — typical RFQ turnaround is 24–48h.