Fagor alarm 4078: ERROR 305: Protocol error on the interface between the power supply module and the driver

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Communication errors were detected on the internal bus between the power supply module and the drive modules. The error cannot be reset: after checking wiring the whole servo system must be powered down/up, and Fagor directs persistent cases to service. The CNC stays stopped with enables removed.

Likely causes

  • Faulty internal interconnect cable/backplane between PSU and drives
  • Defective communication port in PSU or drive
  • Noise/grounding issue on the internal link

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4078 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog