Fagor alarm 4079: ERROR 306: Over-voltage at the power bus (Soft, trigger prior to hardware)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Drive software detected the DC bus trending above its soft limit before the hardware threshold trips. PWM is cut (category 0 stop) and the CNC aborts all channels. Treat exactly like the hard overvoltage: verify the ballast/regeneration chain and deceleration profiles.

Likely causes

  • Missing or defective internal ballast connection
  • External regen resistor open-circuit or undersized
  • Aggressive deceleration of high-inertia or vertical axes
  • Line voltage spikes on the mains input

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4079 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog