RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4080

Fagor alarm 4080: ERROR 307: Under-voltage of the power bus

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Software-detected DC bus undervoltage: the bus fell below the permissible minimum for the supply rating. It is a resettable category 1 stop; the CNC still cancels enables, interrupts all programs and activates the external emergency output. Investigate the mains feed and PSU health.

Likely causes

  • Mains voltage sag below rated (line <380 V AC class)
  • High line impedance under peak current demand
  • Blown PSU fuse or loose bus plates
  • Missing input phase

Triage note: Also grouped as alarm 4011.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4080 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog