RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4091

Fagor alarm 4091: ERROR 500: Incoherent parameters

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The drive's stored parameter set is internally inconsistent (values contradict each other or the hardware configuration). The error deactivates PWM (category 0 stop) and cannot be cleared by reset - reload correct parameters and power-cycle. The CNC remains stopped until the drive completes a healthy start-up.

Likely causes

  • Corrupted drive parameter memory
  • Parameters from a different motor/model flashed into the drive
  • Interrupted parameter download leaving mixed versions

Triage note: Re-download the .MOT/parameter file with WinDDSSetup and cycle power.

Need the part urgently?

Send us alarm 4091 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog