RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4105

Fagor alarm 4105: ERROR 701: Internal: Wrong VeCon board identification

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The drive's identification read-back of the VeCon (control) board returned an unexpected ID, meaning the control electronics do not match the configured hardware. PWM is deactivated (category 0 stop) and the error is non-resettable - power cycle after inspection; replacement of board or drive is normally needed.

Likely causes

  • Control board replaced with an incompatible version
  • ID EEPROM/read circuit fault on the VeCon board
  • Seating/connector problem between boards

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4105 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog