Fagor alarm 4105: ERROR 701: Internal: Wrong VeCon board identification
CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives
What it means
The drive's identification read-back of the VeCon (control) board returned an unexpected ID, meaning the control electronics do not match the configured hardware. PWM is deactivated (category 0 stop) and the error is non-resettable - power cycle after inspection; replacement of board or drive is normally needed.
Likely causes
- Control board replaced with an incompatible version
- ID EEPROM/read circuit fault on the VeCon board
- Seating/connector problem between boards
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
VeCon control board
drive · Common cause
- Request a quote →
DDS / AXD / SPD drive
drive · Common cause