Fagor alarm 4111: ERROR 707: X4 motor feedback board identification error

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The plug-in feedback card at connector X4 (motor feedback input) reports a wrong identification. PWM stays off (category 0 stop) and the error is not clearable by reset; reseat/replace the feedback card and power cycle. The CNC holds the axis stopped until the drive starts cleanly.

Likely causes

  • X4 feedback card of wrong type or unrecognized revision
  • Poor seating of the daughter card
  • Damaged ID EEPROM on the feedback card

Replacement parts