RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4119

Fagor alarm 4119: ERROR 203: Torque overload error

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

With high torque commanded the motor failed to turn freely: speed stayed below GP8 for longer than GP7 allows, i.e., stall detection. PWM is cut (category 0 stop) and the CNC removes enables and interrupts the program on all channels. Free the mechanism; GP7/GP8 may be raised only if the trip is spurious (GP7=0 disables).

Likely causes

  • Axis or spindle mechanically blocked/stalled
  • Two swapped or loose power phases
  • Defective feedback cable or wrong NP116/RV3 (RP5) settings
  • Cutting load exceeding available torque

Need the part urgently?

Send us alarm 4119 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog