Fagor alarm 4136: ERROR 254: Wrong reading of distance-coded reference marks (I0)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

During homing with a distance-coded (O-suffix) scale the drive reads inconsistent mark spacing - absolute-within-20 mm function unreliable.

Likely causes

  • graduations dirty, oiled, or scratched on the glass/steel tape
  • reading gap out of tolerance (head bracket knocked)
  • axis speed outside the allowed window during mark sampling
  • scale head electronics marginal

Triage note: Clean with approved optics cleaner and verify the gap spec first - most E254 calls end at cleaning, not replacement. Confirm homing speed parameter matches scale spec.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • S2OX-1140-5-A-T (match length/code)

    Distance-coded linear scale (current S2/SV2 generation) · Common cause

    Request a quote →
  • SOX/SOP legacy scale (match length)

    Legacy S-series distance-coded scale · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 4136 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog