Fagor alarm 4137: ERROR 308: Over-current at energy return circuit

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Excessive current was detected in the regeneration (energy return) circuit. The drive/system stops with the standard full shutdown; Fagor lists no user fix and directs persistent occurrences to service. Check the regen resistor and its wiring first since they carry this current.

Likely causes

  • Degraded or partially shorted regen resistor
  • Regeneration current beyond resistor rating
  • Wiring/connector fault in the regen circuit
  • Failed chopper transistor in the PSU regen stage

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4137 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog