Fagor alarm 4138: ERROR 309: Short-circuit at the High Side IGBT

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Short-circuit detected on the high-side IGBT of the inverter/output stage. The drive cuts PWM (category 0 stop) and the CNC removes all enables and aborts every channel. Fagor documentation routes this straight to service: the power module is effectively destroyed.

Likely causes

  • Failed high-side IGBT (shorted)
  • Shoot-through caused by gate-driver failure
  • Output short stressing the bridge

Triage note: On older XPS units this state is shown via front-panel LED combination instead of a numeric code.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4138 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog