Fagor alarm 4140: ERROR 311: Short-circuit at the Low Side of the IGBT

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Short-circuit detected on the low-side IGBT of the output bridge. Immediate PWM cutoff (category 0 stop) plus the CNC emergency sequence on all channels. Service/replacement of the drive is required; do not repeatedly reset onto a shorted bridge.

Likely causes

  • Shorted low-side IGBT
  • Gate-driver failure causing shoot-through
  • Motor/cable short damaging the bridge leg

Replacement parts