Fagor alarm 4141: ERROR 312: Low voltage at the driver of the Low Side IGBT

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The gate-driver supply for the low-side IGBT fell below the safe operating level. The drive reacts with an immediate PWM cutoff (category 0 stop); the CNC drops enables and aborts the program everywhere. If it persists after one reset, the driver stage or drive must be serviced.

Likely causes

  • Low-side driver supply defect
  • Degraded IGBT increasing driver load
  • Internal low-voltage supply ripple/failure

Replacement parts