RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4157

Fagor alarm 4157: ERROR 811: Defective Feedback2 encoder (direct/second feedback)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The direct (linear-scale) feedback on X3 fails integrity checks - position loop reference itself is untrustworthy.

Likely causes

  • linear scale reader head failing (LED aging, CCD degradation)
  • scale cable damaged along the traveling chain
  • contamination lifting signal amplitude below threshold

Triage note: Compare PV190 (direct) vs PV188 (motor) position at standstill - a slowly drifting delta condemns the scale head even if the alarm is intermittent. NOTE: 'S100/S120' are not valid Fagor scale types; Fagor linear scales are S/SV (legacy), S2/SV2 (current), LA/SA/GA (absolute).

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4157 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog