Fagor alarm 4177: ERROR 315: The power supply has not started up correctly
CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives
What it means
The power supply failed its start-up sequence, so the DC bus never reached the ready state. PWM is cut (category 0 stop) and the whole CNC remains shut down. For PS-25x supplies Fagor specifically calls out the ballast resistor; otherwise inspect the supply itself.
Likely causes
- Open or degraded ballast resistor (esp. PS-25x)
- Soft-start/precharge circuit failure in the PSU
- Weak mains input or blown input fuse
- Internal PSU control fault
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
Ballast resistor
regen-resistor · Common cause
- Request a quote →
PS / XPS power supply
power-supply · Common cause
Need the part urgently?
Send us alarm 4177 with your machine details — typical RFQ turnaround is 24–48h.