Fagor alarm 4177: ERROR 315: The power supply has not started up correctly

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

The power supply failed its start-up sequence, so the DC bus never reached the ready state. PWM is cut (category 0 stop) and the whole CNC remains shut down. For PS-25x supplies Fagor specifically calls out the ballast resistor; otherwise inspect the supply itself.

Likely causes

  • Open or degraded ballast resistor (esp. PS-25x)
  • Soft-start/precharge circuit failure in the PSU
  • Weak mains input or blown input fuse
  • Internal PSU control fault

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4177 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog