RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4184

Fagor alarm 4184: ERROR 818: Error on the absolute track (FAGOR SSI absolute encoder)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

SSI absolute position cannot be computed - incremental analog component collapsed below ~0.20 Vpp or absolute track unreadable.

Likely causes

  • steel tape/glass disk contaminated or scratched
  • machine speed exceeds encoder rating (absolute track skipped)
  • mounting tolerances violated (gap/alignment)
  • reader head or encoder internally damaged

Triage note: Clean the tape per manual (no solvents on coating), verify max speed vs scale spec, then substitute head. If analog channel reads <0.2 Vpp at the drive with scope, head is done.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • LA-840 (length per axis)

    LA absolute steel-tape linear scale · Primary suspect

    Request a quote →
  • SAF10-420-5-A / SAS-770-3

    SA absolute compact scale (legacy protocols) · Common cause

    Request a quote →
  • HAF-27-D90-2

    Absolute angular encoder (rotary applications) · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 4184 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog