Fagor alarm 4193: ERROR 316: It took too long charging the DC bus of a compact drive

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

In a compact (self-contained) drive, the soft-start charge of the DC bus exceeded the 4-second supervision window, so precharge is considered failed. PWM is cut (category 0 stop) and the CNC stays shut down. This error cannot be disabled; check the crowbar/soft-start components before replacing the drive.

Likely causes

  • Crowbar (internal or external) badly connected or open
  • Defective internal SoftStart/crowbar resistor
  • Blown internal current-limiting fuse of the soft-start stage
  • Weak mains supply prolonging charge time

Triage note: This is the classic 'precharge' error of compact DDS models.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4193 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog