RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4210

Fagor alarm 4210: Error in the SERCOS ring (MST lost)

CNC 8060/8065/8070 SERCOS error · Fagor 8060/8065/8070

What it means

The master synchronism telegram (MST) stopped arriving correctly around the loop and phase 4 collapsed. Because MST is generated by the CNC master and consumed by every slave, the break is usually in the outbound light path shared by all nodes.

Likely causes

  • fiber break on the master output segment
  • master control board (SERCON) transmit fault
  • first slave in line powered off, halting pass-through

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4210 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog