RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4211

Fagor alarm 4211: Error in the SERCOS ring (2 ATs lost)

CNC 8060/8065/8070 SERCOS error · Fagor 8060/8065/8070

What it means

Two consecutive drive-response telegrams (ATs) went missing, indicating the slave(s) stopped echoing their responses and phase 4 was lost. Identifying the defective node tells whether the drive or the ring segment feeding it is at fault.

Likely causes

  • drive hang-up or spontaneous reset
  • ingress fiber to a specific drive damaged
  • Sercos board failure in one drive blocking retransmission

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4211 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog