Fagor alarm 4216: Error in the Sercos ring (synchronism)
CNC 8060/8065/8070 SERCOS error · Fagor 8060/8065/8070
What it means
General synchronism loss on the Sercos bus: nodes no longer agree on the cycle timing and phase 4 drops. The manual attributes it to connection problems, parameterization issues or Sercos-board problems, and recommends verifying the whole ring before contacting service.
Likely causes
- fiber optic path degraded anywhere in the loop
- timing/telegram parameterization mismatch
- Sercos interface board failing under temperature
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
SERCOS fiber-optic ring cable assembly
cable · Common cause
Need the part urgently?
Send us alarm 4216 with your machine details — typical RFQ turnaround is 24–48h.