RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 5013

Fagor alarm 5013: Error when reading the digital inputs of the PLC

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

The cyclic read of remote digital inputs allocated to the PLC image failed. Configuration of the digital-input modules (NDIMOD) or the integrity of the CAN bus to the I/O nodes is compromised. Intermittent versions correlate with cable damage, noise or marginal 24 V supplies.

Likely causes

  • NDIMOD configuration mismatch with actual modules
  • CAN cable/termination fault to remote I/O node
  • node power dip causing missed frames

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 5013 with your machine details — typical RFQ turnaround is 24–48h.