Fagor alarm 5036: Output over-current
Fagor CAN/remote I/O error · Fagor 8060/8065/8070
What it means
The indicated CAN node reports excessive consumption on its digital outputs. As a precaution the system zeroes every output of that module, so solenoids and lamps fed by it drop out while the rest of the machine stays alive.
Likely causes
- shorted solenoid valve, clamp or indicator lamp on one output point
- total load on the module above its rated current
- damaged output driver stage inside the remote module
Triage note: Isolate loads one at a time: a shorted actuator coil will keep re-tripping even a healthy replacement module.