Fagor alarm 5036: Output over-current

Fagor CAN/remote I/O error · Fagor 8060/8065/8070

What it means

The indicated CAN node reports excessive consumption on its digital outputs. As a precaution the system zeroes every output of that module, so solenoids and lamps fed by it drop out while the rest of the machine stays alive.

Likely causes

  • shorted solenoid valve, clamp or indicator lamp on one output point
  • total load on the module above its rated current
  • damaged output driver stage inside the remote module

Triage note: Isolate loads one at a time: a shorted actuator coil will keep re-tripping even a healthy replacement module.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • RIO70 16-output half-module / RIO5 output module

    remote I/O digital output module · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 5036 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog