RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 6000

Fagor alarm 6000: Feedback alarm (parameter FBACKAL active)

CNC 8060/8065/8070 feedback alarm (analog axes) · Fagor 8060/8065/8070

What it means

Analog-axis feedback alarm at the CNC counter input. Differential TTL: broken A/B (or inverted) wire, input disconnected. Differential 1 Vpp sinusoidal additionally trips when amplitude >~1.45 Vpp or <~0.4 Vpp or A/B quadrature phase-shift is wrong.

Likely causes

  • feedback cable conductor fracture (works cold, fails warm - classic thermal intermittent)
  • connector contact corrosion at scale head
  • scale head amplitude drift out of the 0.4-1.45 Vpp window
  • counter/feedback input stage on COMPCI-side hardware failing

Triage note: Scope pins A-/A at the drive/CNC input: amplitude inside 0.4-1.45 Vpp and ~90 deg shift = healthy scale, suspect cable/input. TRIAGE NOTE: 'S100/S120' appear in some ask-lists but are NOT Fagor products (Siemens SINAMICS S120 is a drive); Fagor scales are S/SV, S2/SV2, LA/SA/GA series.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 6000 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog