RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 6001

Fagor alarm 6001: Tendency test alarm activated

CNC 8060/8065/8070 feedback alarm (analog axes) · Fagor 8060/8065/8070

What it means

Runaway detector: axis saw sustained positive feedback (position running away from command) longer than ESTDELAY.

Likely causes

  • command sign (AXISCHG) or feedback direction (LOOPCHG) inverted after rewiring/parameter reload
  • encoder counting direction flipped by swapped A/B phases
  • actual runaway from failed velocity loop in the drive

Triage note: Safety-relevant: axis can accelerate uncontrollably. First jog at minimal feed with hand on E-stop after ANY parameter restore or feedback rewiring.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • EC-P-D / EEC-SP-x

    Feedback cable (verify A/B not transposed) · Common cause

    Request a quote →
  • AXD/ACD (generation-match)

    Drive module if loop hardware at fault · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 6001 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog