Fagor alarm 6002: The PLC program is not running

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

Monitored at startup and during operation: the PLC executive is stopped, so machine logic (emergency chain, lubrication, tool change) is dead even though the CNC itself runs. Happens after software updates or when someone stopped the PLC from the monitor and forgot to restart it. Set the PLC to run and compile if needed.

Likely causes

  • PLC halted manually during maintenance
  • PLC stopped after software update without restart
  • fatal PLC execution fault stopping the executive

Need the part urgently?

Send us alarm 6002 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog