Fagor alarm 6003: External emergency activated

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

The PLC mark _EMERGEN is deactivated, telling the CNC that an external emergency condition exists - typically a pressed E-stop somewhere in the machine chain. Trace the physical E-stop loop first, then review _EMERGEN logic in the PLC if no button is pressed.

Likely causes

  • E-stop button pressed or faulty
  • broken wire/open contact in the emergency chain
  • _EMERGEN logic inverted or not driven correctly in PLC program