Fagor alarm 6006: One or several CAN nodes do not respond

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

One or more remote nodes dropped off the CAN bus during operation - the error sub-code tells how many were lost (CANfagor) or identifies the silent module (CANopen). Typical triggers are node resets from supply dips, short circuits or marginal contacts. Diagnosis mode lists which modules remain recognized.

Likely causes

  • 24 V supply dips resetting a node
  • CAN connector vibration damage / broken conductor
  • short circuit on node I/O dragging down the node
  • node electronics failure

Triage note: Sub-codes: -3/-4/-5/-1/-6 map to 1/2/3/>3 nodes lost on CANfagor bus; 2/3/4 are CANopen timeout, toggle-bit and wrong-state respectively.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • remote CAN I/O node power feed (ribbon/PSU per install manual)

    cable · Common cause

    Request a quote →
  • affected remote CAN node module (identify via diagnosis mode)

    board · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 6006 with your machine details — typical RFQ turnaround is 24–48h.