Fagor alarm 6006: One or several CAN nodes do not respond
Fagor CAN/remote I/O error · Fagor 8060/8065/8070
What it means
During execution the CNC loses contact with one or more remote nodes (I/O groups, keyboards) because they reset, short out or perform poorly. With the CANfagor protocol the code tells how many nodes were lost (-3/-4/-5 = 1/2/3 nodes, -1/-6 = more than three); with CANopen it flags timeout (2), toggle-bit error (3) or a node answering in the wrong state (4), and the error window names the offending module.
Likely causes
- node 24 V supply dropout or brown-out
- CAN cable damage, bad crimp or water ingress at one tee junction
- failed remote module dragging the bus down
Triage note: Confirm in diagnosis mode that the CNC still enumerates all modules before replacing any hardware.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
RIO5 / RIOW / RIO70 series module
remote I/O module · Common cause
Need the part urgently?
Send us alarm 6006 with your machine details — typical RFQ turnaround is 24–48h.