Fagor alarm 6011: CAN error in remote node
Fagor CAN/remote I/O error · Fagor 8060/8065/8070
What it means
A remote node itself reports an error over the bus on 8060/8065 systems; the window indicates which module type raised it (analog I/O, counters, digital I/O, PT100 inputs, keyboard handwheel, probes, jog/alphanumeric keyboards, general I/O node failure). CANfagor sub-codes include controller overrun (1), BusOFF (2), FIFO overrun (3), warning threshold (4), COMPCI presence-control failure (11), node reset (12) and transmission failure (13).
Likely causes
- bus disturbance seen only by one node (stub cable, terminator)
- node reset caused by supply glitch, short-circuit or watchdog trip
- module electronics degradation
Triage note: Treat sub-code 12 exactly like alarm 6034 (Reset in CAN node): verify the node supply before condemning the module.
Need the part urgently?
Send us alarm 6011 with your machine details — typical RFQ turnaround is 24–48h.