RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 6023

Fagor alarm 6023: Error when initializing the handwheel counter

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

At 8060/8065 startup the pulse-counter channel reserved for an electronic handwheel does not exist in the hardware as configured; the error window names the affected counter. Jogging via that handwheel is impossible until configuration matches hardware.

Likely causes

  • Jog-table/machine-parameter handwheel assignment pointing at a nonexistent counter
  • handwheel interface module absent or failed
  • handwheel cable disconnected making the channel undetectable

Triage note: Swap handwheel connections first: if the error follows the wheel to another port, the wheel is at fault; if it stays, it is the counter/config.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 6023 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog