RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 6034

Fagor alarm 6034: Reset in CAN node

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

A remote CAN node rebooted during operation; the error window shows which node number. Momentary resets come from supply glitches or watchdog trips inside the node. If the same node recurs, verify its 24 V feed and ribbon connections, then plan replacement of the module.

Likely causes

  • unstable 24 V node supply (PSU ripple, loose fuse)
  • watchdog reset inside node electronics
  • short circuit on node I/O channel

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • node 24 V power wiring/connector per install manual

    cable · Common cause

    Request a quote →
  • affected remote CAN node module (identify number via error window)

    board · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 6034 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog