RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 6034

Fagor alarm 6034: Reset in CAN node

Fagor CAN/remote I/O error · Fagor 8060/8065/8070

What it means

A node on the 8060/8065 CAN bus has rebooted while the CNC was running; the error window identifies which node number reset. Fagor advises verifying the node is properly supplied first, then checking the bus, and replacing the node if resets continue.

Likely causes

  • momentary 24 V dropout at that group (loose fuse, tired supply)
  • internal watchdog trip in the module
  • bus noise severe enough to crash the node controller

Triage note: Log how often it recurs: a one-off after a shop power event is benign, repeats point at supply or module.

Need the part urgently?

Send us alarm 6034 with your machine details — typical RFQ turnaround is 24–48h.