Fagor alarm 6036: There is no voltage supply for local I/O

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

The local I/O integrated in the ICU/MCU central units has no external 24 V supply, so onboard inputs/outputs are dead while the CNC itself boots fine. Restore the 24 V feed from the machine cabinet. This is pure wiring/power, not a CNC board fault, unless the internal fuse opened.

Likely causes

  • 24 V feeder to ICU/MCU local I/O open (fuse, terminal)
  • cabinet PSU channel for local I/O tripped
  • wiring error after cabinet service

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 6036 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog