Fagor alarm 6048: External feedback alarm
CNC 8060/8065/8070 feedback alarm (analog axes) · Fagor 8060/8065/8070
What it means
The feedback device connected to the local feedback input asserts its own alarm output. The encoder or scale is telling the CNC it is unhealthy internally - the CNC simply forwards the device-level alarm.
Likely causes
- internal LED/lamp degradation in the scale reading head
- contamination (coolant film, chips) on glass scale or disk
- encoder electronics failure flagged by self-test
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
SV-C / S2 / LA / EXA linear scale or H-series encoder
scale · Common cause
Need the part urgently?