Fagor alarm 6050: Short-circuit at the local I/O (over-current alarm)

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

The current-limited local I/O driver detected an over-current, meaning something wired to the local outputs is shorted or overloaded. The protection latches until the fault clears. Disconnect loads one by one to isolate the shorted solenoid, lamp or harness.

Likely causes

  • shorted solenoid valve or indicator lamp on a local output
  • chafed wire to ground in output harness
  • moisture ingress in connector blocks

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • field device wired to shorted local output (locate by isolation)

    cable · Common cause

    Request a quote →