Fagor alarm 8332: #WARNING/#ERROR["Text <%d>"<,value>]/[integer]
CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070
What it means
Syntax error raised when the #WARNING or #ERROR high-level instruction is programmed incorrectly in the part program. These instructions let programs and macros emit their own warnings/errors with formatted text, complementing the PLC ERR-resource mechanism. Correct the string/value argument layout per the programming manual.
Likely causes
- malformed quoted text or missing <%d> placeholder pairing
- integer argument form used with wrong bracket structure
- instruction placed in a context that forbids it
Triage note: #ERROR aborts/interrupts like an error; #WARNING presents a non-blocking warning - choose per desired machine behavior.