What it means

Syntax error raised when the #WARNING or #ERROR high-level instruction is programmed incorrectly in the part program. These instructions let programs and macros emit their own warnings/errors with formatted text, complementing the PLC ERR-resource mechanism. Correct the string/value argument layout per the programming manual.

Likely causes

  • malformed quoted text or missing <%d> placeholder pairing
  • integer argument form used with wrong bracket structure
  • instruction placed in a context that forbids it

Triage note: #ERROR aborts/interrupts like an error; #WARNING presents a non-blocking warning - choose per desired machine behavior.