Fagor alarm 85850: G8585 not allowed with temporary origin G92 active
CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070
What it means
The G8585 profile-grinding support cycle was programmed while a temporary coordinate preset (G92) was still in effect, mixing two origin systems. Cancel the G92 preset before calling G8585. Companion codes 85851+ cover parameter conflicts specific to this cycle family.
Likely causes
- G92 preset left active from previous op
- grinding macro setting G92 internally without cleanup
- program structure calling G8585 inside preset block range
Triage note: The whole 85000-85999 band belongs to the G8585 grinding-cycle option; errors there cite the exact forbidden parameter combination.
Need the part urgently?
Send us alarm 85850 with your machine details — typical RFQ turnaround is 24–48h.