What it means

A PLC program declared/referenced an error resource outside ERR1-ERR1024. The ERR range is exactly how machine builders create their own machine-specific alarms on the 8060/8065/8070: the OEM assigns numbers, defines texts, and activates them from ladder logic. Any OEM alarm you see numbered within the machine-builder's chosen band originates here.

Likely causes

  • ERR index typo outside 1-1024
  • OEM numbering plan colliding with architecture limit
  • converted legacy PLC using old family's error count

Triage note: Structure tip for troubleshooting: Fagor-reserved codes are numeric (0001-9xxx, 20000+, 23000+, 80000+); machine-specific alarms activated via ERR resources appear with the OEM's own numbering and texts.