Fagor alarm 9014: Fatal error. Duplicate module or not allowed

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

Raised while compiling the PLC program: the PRG or CY1 module appears more than once, or two periodic modules share the same period. Only one PRG and one CY1 are permitted per project; periodic modules must differ in period. Merge duplicated logic into a single module and recompile.

Likely causes

  • PRG or CY1 module duplicated in project
  • two CY2-type periodic modules with identical period value
  • imported library block colliding with existing module

Need the part urgently?

Send us alarm 9014 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog